Abstract
INTRODUCTION
Tau positron emission tomography (PET) tracers differ in kinetics, binding properties, and quantification pipelines, complicating cross-study comparisons. The CenTauR approach provides a unified framework for harmonizing tau PET quantification across tracers.
METHODS
We defined a tracer-agnostic “Standard Method” using Statistical Parametric Mapping 12, standardized regions of interest, and harmonized acquisition parameters. Using data from five tau tracers—[18F]flortaucipir, [18F]MK-6240, [18F]PI-2620, [18F]RO948, and [18F]GTP1—we applied the Joint Propagation Model to derive linear equations converting regional standardized uptake value ratios into the tracer-independent CenTauR scale. Validation included independent cross-sectional, longitudinal, and test–retest datasets across multiple cohorts.
RESULTS
The CenTauR scale yielded highly consistent regional values across tracers, with strong cross-tracer agreement and robust performance in external validation cohorts. We also expressed clinically relevant cut-points and staging boundaries on the CenTauR scale.
DISCUSSION
The CenTauR approach enables harmonized, tracer-independent quantification of tau PET, supporting reproducibility across studies and improving interpretation in clinical research and multicenter trials.